Control Jacob Method for Transient Flow in a Confined Aquifer





Tool Parameters
Values displayed with a may be changed ... click on a value to display an entry form ... or use the arrows right of a value to select from a list.
Tool Behaviour
This tool exhibits spreadsheet-like behaviour ... change a value and related values are re-calculated automatically.
EduMine Toolkit

See opportunities for tool authoring with EduMine.
Notes on Jacob Method for Transient Flow in a Confined Aquifer
  • Select the required output, then set the other parameters to the required values.
  • Transmissivity (T) = K * D
For an explanation of the parameter "u" and to determine the accuracy of Jacob's method see accuracy.
For equations, assumptions and references see equations.

Tool developed and